骆科吉,禹 元,林廷全,骆 彬,吴建虎.3 200 t/d熟料回转窑提产降耗改造实践[J].水泥工程,2023,36(1):40-42 |
3 200 t/d熟料回转窑提产降耗改造实践 |
Practice of 3 200 t/d clinker rotary kiln production improvement and consumption reduction |
|
DOI: |
中文关键词: 熟料生产线,热平衡测试,提产降耗,预热器,烟室 |
英文关键词: clinker produtction line, heat balance test, increase production and reduce consumption, preheater, flue chamber |
基金项目: |
|
摘要点击次数: 506 |
全文下载次数: 0 |
中文摘要: |
为把握系统的生产运行状况、进一步优化系统、提产降耗,2018年汪洋建宝水泥有限公司委托专业公司对其30200 t/d熟料生产线进行了热平衡测试。基于热平衡测试数据,分析了该系统存在的主要问题,在此基础上提出了改造措施。 |
英文摘要: |
In order to grasp the production and operation status of the system, further optimize the system, increase production and reduce consumption, Wangyang Jianbao Cement Co., Ltd. entrusted a professional company to conduct a heat balance test on its 3 200 t/d clinker production line in 2018. Based on the heat balance test data, the main problems of the system are analyzed, and the improvement measures are proposed. |
查看全文
查看/发表评论 下载PDF阅读器 |
关闭 |
|
|
|