文章摘要
马 刚,唐国成,董春荣.浅析接地装置防腐及措施[J].水泥工程,2014,27(4):64-66
浅析接地装置防腐及措施
Anticorrosion of earthing device and measures
  
DOI:
中文关键词: 接地装置,腐蚀原因,防腐措施,施工要点
英文关键词: grounding device,corrosion causes,anticorrosion measures,construction points
基金项目:
作者单位
马 刚 江苏建兴建工集团有限公司 
唐国成 江苏建兴建工集团有限公司 
董春荣 江苏科行环保科技有限公司 
摘要点击次数: 1294
全文下载次数: 0
中文摘要:
      接地装置是接地体和接地总线的总称,保持其良好接地状态是确保人身、设备以及构筑物安全的重要环节。使用过程中,接地装置尤其容易遭受腐蚀破坏,进而会影响其接地防护效果。文章详细分析了接地装置腐蚀的部位、原因和种类;在此基础上,介绍了五类防腐技术措施;此外,对接地装置的施工要点也进行了分析。
英文摘要:
      Grounding device is a general term for grounding body and grounding bus, and keep its good grounding state is an important link to ensure person, equipments and structures safety. And in using process, grounding device is particularly vulnerable to corrosion damage, and will further impact the grounding protection effect. The corrosion parts, causes and types of earthing device were analysed in detail, and based on that, five kinds of anticorrosion technology measures were introduced. Additionally, the construction points of grounding device were also analysed.